Copper Power Feeder Conductors. Lightweight Aluminum Interlocked Armor with Overall PVC Jacket.
600 Volts. THHN/THWN-2 Insulated Singles .
Bare Copper Grounding Conductor.
Sizes 1 AWG through 750 kcmil.

Product Description

APPLICATIONS
Armorlite ® Type MC Cable - "flame retardant sunlight resistant PVC Jacket" is suitable for use as follows:
• Direct burial applications, installation in concrete and where exposed to cinder fills, strong chlorides, caustic alkalis, or
vapors of chlorine or of hydrochloric acids.
• Branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
• Power, lighting, control, and signal circuits.
• Fished or embedded in plaster.
• Concealed or exposed installations
• Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
• As aerial cable on a messenger.
• Installation in cable tray and approved raceways.
• Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).
• Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.

CONSTRUCTION
Armorlite ® Type MC Cable - "PVC Jacketed" is constructed with soft-drawn, copper Type THHN/THWN-2
conductors rated 90°C wet or dry, and a bare copper grounding conductor for sizes 1/0 AWG and larger. The conductors are
cabled together and a binder tape is wrapped around the assembly. Aluminum interlocking armor is applied over the
assembly. A black, flame retardant, sunlight resistant, PVC jacket is applied over the armor. The jacket is available in blue or
gray colors upon request, subject to economic order quantities. Standard PVC Jacket will not meet "Limited Smoke or LS
Rating". Optional SOLONON Jacket can be provided for "LS" Rating.

 

Phase ConductorNeutralAprox Dimaeter Over Armor
Weight Per 1000 feet (lbs.)Allowable Ampacity
Size (AWG)Size (AWG)Complete Cable (Inches)
75C90C
1/36 Green Insulated1.2031252
130150
1/46 Green Insulated1.3511585
130150
1/0-36 bare1.2421463
150170
1/0-46 bare1.3621863
150
170
2/0-36 bare1.3391758
175195
2/0-46 bare1.4912322
175195
3/0-34 bare1.4492175200225
3/0-44 bare
1.7342894200225
4/0-34 bare1.5702662
230260
4/0-44 bare1.7493507
230260
250-34 bare1.7373178
255290
250-44 bare1.9134086
255290
350-33 bare1.9604252
310
350
350-43 bare2.1625493
310350
500-32 bare2.2385829380430
500-42 bare2.4777642
380430
750-31 bare
2.6758537475535
750-41 bare
2.96011,111
475535
 
Call Us Today at (516) 606-6537 For The Best Prices On Wire & Cable!
Visit Our Nassau Wire & Cable Blog Here!

Go Green With Nassau Wire & Cable!

Community Poll

For 120V Single Phase 200Amp Service Are Three or Four Wires Required?